ACCESS VIRUS RACK XL OS5 159
System Exclusive Implementation
PDF VERSION - RESTRICTIONS APPLY
the same Performance Controllers. The Sound
Parameters are stored with a Single Sound. If
more than one Multi Part is set to the same MIDI
channel, the Sound Parameter is receiced only
by the Multi Part with the lowest part number.
Example: B0,21,40 Set oscillator balance (21
hex = 33 dec) on MIDI channel 1 to the middle
position (40 hex =64 dec).
POLYPHONIC PRESSURE MESSAGE
(ONLY PAGE B)
Ac Status byte, c=MIDI channel
nn Parameter Number 0..127
(see parameter list Page B)
vv :Parameter Value 0..127
see parameter list Page B)
Example: A2,07,25 Control LFO3 Rate on MIDI
channel 3 (!).
SYSTEM-EXCLUSIVE-MESSAGE
F0 Start of System Exclusive
00 Manufacturer ID 1
Access Music Electronics
20 Manufacturer ID 2
Access Music Electronics
33 Manufacturer ID 3
Access Music Electronics
01 Product ID (Virus)
dd Device ID
00..0F individual; 10: omni.
... [message]
F7 End of System Exclusive
SYSEX PARAMETERCHANGE
7x Parameterchange
70:page A;
71:page B;
72:page
C pp Part number
00..0F Multi part 1..16;
40: Single
nn Parameter Number
0..127 (see parameter list)
vv Parameter Value 0..127
(see parameter list)
{F0,00,20,33,01,dd,7x,pp,nn,vv,F7}
The SysEx Parameterchange affects one of
the sixteen single edit buffer in Multi Mode ad-
dressed by the part number (00..0F) or the Sin-
gle buffer in Single Mode (part number 40). If a
global parameter or a Multi parameter is ac-
cessed, which is not part-sensitive (e.g. Input
Boost or Multi Delay Time), the part number is
ignored.
Example: F0,00,20,33,01,10,70,05,28,5F,F7
Set Cutoff on Part 6 to decimal value 95. (10:
device ID omni; 70: page A, 05: part 6; 28: pa-
rameter Cutoff, 5F: decimal value 95)